The PCI/PXI system automatically allocates all device resources, including the base address and interrupt level. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. The PXIe‑8842 is an embedded controller for PXI systems that you can use for processor-intensive modular instrumentation and data acquisition applications. For instance, if you select the NI PXIe-1075 chassis, most of the Counter/Timer cards. (217) 352-9330 | sales@artisantg. When setting up the power up configuration for the PCIe-6509, you have the option to choose between pull-up, pull-down, and tristate. PXI Digital I/O Module Adapter Cards. Solution. Features: 96 bidirectional DIO channels (5 V TTL) High-current drive (up to 24 mA sink or source)The USB-8451 is specifically designed for I2C and SPI communication. Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF Product Support Resources. PXI‑6529 devices are ideal for a variety of applications from automotive design, industrial factory automation, and machine control to aerospace, laboratory research, and biomedical applications. NI is now part of Emerson. User Guide and Specifications document. The NI PXIe 8510 offers a CAN HS/FD and/or LIN interface with equipment selectable NI-XNET handset links, a NI-XNET driver for creating casing and signal applications in LabVIEW, LabWindows ™/CVI, and C/C ++, along with a driven DMA motor for coupling to host memory to limit message latency. This article shows how to locate example or sample code to program an NI-DAQmx driver in ANSI C, C++, . Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. The range for output voltages is from -0. M9195B. Here, you can click the Chassis tab and select the PXI Express Chassis you are interested in purchasing. They are a useful reference to perform basic S-Parameter measurement in a benchmarkable fashion. 50 USD 0. On another card 6284, with DIO's, I can set them individually. After the connector block I have two more custom cable assemblies that attach to each other. 48-Channel, Sink/Source Inputs, Channel-Channel Isolated PXI Digital I/O Module. Can I programmatically change the digital output of PXI 6509 from 5V to 3. The technical storage or access that is used exclusively for statistical purposes. I wanted to learn how to work with the 6509 so I set up a simulated device in MAX. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. PXIe is a standard that leverages the. Free shipping on many items | Browse your favorite brands | affordable prices. SPECIFICATIONS PXIe-1092 This document contains specifications for the PXIe-1092 chassis. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100Home Support Documentation Product Certifications PXI-6509 Product Certifications. Re: PXI-6509: Are there any IBIS models available? davidraj. NI-DAQmx. Currently, I lost the computer with NI DAQ card, and don't know the exact model number. Remove all PXI (e) peripheral modules from the chassis. For network devices, if the CompactDAQ and its modules have been working before, the Status Code: -88705 can also appear if the PC and the CompactDAQ have not been switched on/off in the correct order. The PCIe-6509 (Part number: 779976-01, 196640C-01L) is an advanced Digital I/O Device from National Instruments. Part Numbers: 189700B-01, 778792-01, 189700E-01L. NI 6509. The PXIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). Hello , I am using a ni PXI-6509 card for my application. Withan NI. see the attached picture). Instead I have a very strange behaviour trying to use port 0 (I tested also port 3 obtaining same behaviour) to r. 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module —The PXI‑6509 can directly drive external digital devices such as solid-state relays (SSRs). GPIB, Serial, and Ethernet. A valid service agreement may be required. You can request repair, RMA, schedule calibration, or get. 思科6509. Using programmable power-up states, you can. PCI Express, 96-Channel, 5 V, TTL/CMOS, 24 mA Digital I/O Device. If a computer or application fault occurs, the PXI‑6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. To be more specific, is there a way on my DIO Module, PXIe-6509, to set a line to ON. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. This model has a PCI Express bus connector. All Forum Topics; Previous Topic; Next Topic; What do you need our team of experts to assist you with? Request a quote Find the right product Place an order Get support on a product. This item has an extended handling time and a delivery estimate greater than 9 business days. A PXIe. PCI Express, 96-Channel, 5 V, TTL/CMOS, 24 mA Digital I/O Device. 142931C-01L. 5 V to 5. See all Driver Software Downloads. NI-DAQmx driver software. Re: pxi-6509 neccesary connector block JesusG. You can configure each port for input or output, and no external power supply is required for outputs. Attach the CAL-4309 terminal block to. We are using the change-detection feature of this. Specifications. I am using a PXIe-6509 and LabVIEW 2020 to output digital signals. 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module —The PXI‑6509 can directly drive external digital devices such as solid-state relays (SSRs). Using programmable power-up states, you can configure the initial output states in. NI will still provide support for the controller if that PXI (e) controller still has (or previously had) support for that OS. e. 必读文档 ni-daqmx 和daq 设备安装指南 安装新的硬件设备前,应先安装软件。 安装应用软件 请安装ni 应用软件(例如,ni labview)或其他应用程序开发环境(ade) (例如,Search results for: PXI-6509. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. Measurement Category I is for measurements performed on circuits not directly The PCI-6509 is run using the NIDAQmx driver software which can be programmed using application development environments (ADEs) such as LabVIEW or LabWindows/CVI. A chassis may include support for both PXIe and PXI. A valid service agreement may be required. Hi; I must do a high level function to write/read a DIO PXI-6509 port I am using NIDAQmx library functions as low level functions. Re: How to create a channel for a PXI-6509. However, you may need more references to understand how to apply this to your model. This is the only form factor. NI Employee (retired) 06-08-2017 01:05 PM. To receive our suppliers' latest quotation, please click View Today's Offer >> Back to Top. 1. NI-VISA. Description: Low-Cost Industrial Digital I/O-5 V TTL/CMOS. The technical storage or access that is used exclusively for anonymous statistical purposes. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. Manufacturer: National Instruments Corporation. You can configure each line for input or output and you also can configure each line with a user-configurable pull-up or pull-down resistor. The PXIe-8881 is an Intel Xeon 8-Core embedded controller for PXI Express systems, You can use this PXI Controller for processor-intensive RF, modular instrumentation, and. I currently have a PXIe-S5090 Vector Network Analyzer (VNA) and wanted to know where I can find the software needed for this device. I'm think to build a tool to monitor all those pin output states, in this way we can know which relay is on or off and can easily find. 1/7; Devices No Longer SupportedA brief search through the forums for "digital", "filter" and "6509" did not show anything specific. You can configure each port for input or output, and no external power supply is required for outputs. But when I attempt to comfigure another. Note For information about using the USB-6509 device, refer to the NI USB-6509 User Guide and Specifications document. You can request repair, RMA, schedule calibration, or get technical support. Title: PXI-6509 Letter of Volatility - National Instruments Keywords "PXI-6509, letter of volatility" Created Date: 5/16/2023 12:26:29 AMI don't try with PXI 6509, I will inform you when I could. Faris, Hooking the inputs from Port 0 to the outputs from Port 1 works, but what I'm trying to do is like on the older 6508 is have the channels come up in a high state (5 volts) when the unit is powered up and then ground the channels to change the state (0 volts). The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. You can configure each port for input or output, and no external power supply is required for outputs. For those lines. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. for pricing. They are compatible with TTL, CMOS, and 5 V digitallogic levels. Physical Characteristics Printed circuit board dimensions Standard 3U PXI Dimensions (without connectors) 14. Note For information about using the USB-6509 device, refer to the NI USB-6509 User Guide and Specifications document. Input Lines. NI 6509. CALIBRATION PROCEDURE PXIe-4309 32 Ch (8 ADC), 2 MS/s, 18 - 28 bit, Flexible Resolution PXI Analog Input Module This document contains the verification and adjustment procedure for the PXIe-4309 module. Using programmable power-up states, you can configure the initial output states in. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. A valid service agreement may be required. In contrast, the PCI-6509, PXI-6509, and USB-6509 cannot be configured line-by-line for input or output. You can configure each port for input or output, and no external power supply is required for outputs. 4. 0 V. 6509 Bella Vista Dr, Victoria, BC V8Z 6Y4 is currently not for sale. use NI-Spy for checking communication data. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. 2. You are limited by your software. PXIe-6509 96-channel, 5 V TTL/CMOS, 24 mA PXI Digital I/O Module Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Legal Information Limited Warranty This document is provided ‘as is’ and is subject to being chan ged, without notice, in future editions. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. 06-04-2009 08:39 AM. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Note For information about using the USB-6509 device, refer to the NI USB-6509 User Guide and Specifications document. 修理、RMA、キャリブレーション予定. With our deep portfolio of over 1,000 modules, we provide the assurance that you can optimize your test system switching and simulation to exactly fit your needs. 1、We can set PXI-6509 Power up state from MAX, I set port1 for input and the powerup state is tristate. S. You can request repair, RMA, schedule calibration, or get. . 03-16-2022 04:28 PM. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. Input Lines. A valid service agreement may be required. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. As I found out, NI PXI-6508 and NI 6509 (PCI 6509 or USB NI-6509) is compatible with my 100-pin cable. Note For information about using the USB-6509 device, refer to the NI USB-6509 User Guide and Specifications document. PXI - PXI: All NI PXI controllers are compatible with all NI PXI chassis, although bandwidth limitations of older controllers should be taken into account. PXI Digital I/O Module. PCI-6503 PXI. A PXI-6509 cannot do hardware timing. You can configure each port for input or output, and no external power supply is required for outputs. To properly sample things at several MHz, you will want to go with something more like a PXI-6508 (10MHz), PXIe-6536 (25MHz), or PXIe-6537 (50MHz). Solution. When you are installing DAQmx driver, be sure to select the corresponding . The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. Manufacturer. net examples for PCIe-6509. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. Price may vary with addition of accessories and services. PXIe Bus Enumeration. Signal Name. Contact us Please select your country. TheNI. Individually access inputs and outputs on single port (PXI-6509. The device base address is mapped into PCI memory space. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. A dialog box should open containing information about the firmware image selected. According to the electrical tech who wired the machine, I need to turn OFF the digital output (DO) and then configure the line as a digital in (DI) to change the impedance so that the output does not "float". Page: 5 Pages. pxi-6509 input wrong. By using NI-DAQmx with LabWindows/CVI, you can take full advantage of multithread technology and memory-mapped registers to achieve up to 40 times faster execution speed. Author. 1. The PXIe-1095 features a high-bandwidth backplane and up to 82 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. The fixed pattern is also a good idea. PXIe-6509 96-channel, 5 V TTL/CMOS, 24 mA PXI Digital I/O Module This document lists specifications for the PXIe-6509 96-channel, 5 V TTL/CMOS, 24 mA PXI Digital I/O Module. Do not connect the PXIe-6509 to signals or use for measurements within Measurement Categories II, III, or IV. Francis Rattenbury. PXI-6508. 96. Electrical The following section provides information about the PXIe-1092 AC input and DC output. PXIe, 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. Detailed Description. ) Weight 140 g. com. When I set certain bits high, I'm getting "glitches" or crosstalk with amplitude of 3-4 Volts and duration of 20-50 nanoseconds. NI-VISA. Quantity. Hi Tiana_I , I wasn't able to find anyting about an IBIS model for the PXI-6509. Updated 2023-07-13. Fax: (240) 376-1381. PXIe-6509 寸法図 National Instruments PXI-6509 96-Channel Digital I/O Interface Module. Locate and expand the chassis needing the firmware update. It seems like it might. Trusted Seller. My Keysight LXI based SICL / LAN instrument is timing out on the. ni pxi 7841r 说明书. Do you have an example of a Pyton program for me to. Ne connectez pas le PXIe-6509 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV. Additional Information The PCI-6509, PXI-6509, and USB-6509 modules have 12 ports with 8 lines per port that are bi-directional, but each port must configured on a port-by-port basis for input or output. Some hardware accessories may not yet reflect the NI-DAQmx terminal names shown here. National Instruments PXI peripheral cards adhere to this standard. Email: PXI-6509 National Instruments PXI-6509 96-Channel Digital I/O Interface Module from National Instruments | Buy Today from Artisan. Click OK to write the settings to the device. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. The question is, what is the better way to do this? option1: <pseudocode> high_level_function() { 1. Contact us with questions. Refer to the PXIe-6509 Specifications on ni. PXI-6509 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - PXI DIGITAL I/O MODULE, 96CH, 5V, TTL/CMOS, 24MA,. The TCP steps use the TestStand CVI Adapter to communicate with a DLL created with LabWindows/CVI. Other Names. DAQmxCreateDOChan / DAQmxCreateDIChan 3. This page is actually only relevant to the PCIe version of the 6509 card. The PXI‑6509 can directly drive external digital devices such as solid-state relays (SSRs). The technical storage or access that is used exclusively for anonymous statistical purposes. The PXI‑6508 uses four, 24‑bit. for pricing. This page provides dimensional drawings for the PXIe-6509. Phone: (217) 352-9330. Its driver is NI-845x. This document contains information about using the PCI-6509, PXI-6509, and PCIe-6509 data acquisition devices with the NI-DAQmx driver software. user Guide and Specifications document. You can configure each line for input or output and you also can configure each line with a user-configurable pull-up or pull-down resistor. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. 01-17-2007 01:19 PM. 5 V to 5. The fourth DM has a "Bus Number" property value of "0x28". Output Lines. Hi All, I am setting up a self test application that is supposed to loopback test all 12-ports by connecting ports 0-5 to ports 6-11 (bit 0 to bit 0 etc). Jan 27, 2014 01/14. 25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module. 185c65098c288. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. Migrating existing. Why can this happen, it also happens on another PXI system. 7 straight on ground without a resistor. USB‑6509 是一款工業級、匯流排供電的 USB 裝置,可直接驅動固態延遲繼電器 (SSR) 等外接數位裝置。. Find many great new & used options and get the best deals for National Instruments PXI-6509 Digital I/O 96 Channel at the best online prices at eBay! Free shipping for many products!It´s neccesary to work that pxi-6509 is joined to connector block (i. Try searching for what you need. Extensive range to meet your sensor acquisition needs. The NI PCIe-6509 Digital I/O Device has the voltage range of 0 to 5 volts for the digital inputs only. TheNI. PXE1610CDNPMFD10XTMA1. . 5 Cards: NI PXI-6509(x2), NI PXIe-4303(x3), NI PXIe-6739(x2) Host PC: standard Windows 7 PC, DAQmx version 15. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to. Please see the National Instruments' website for the NI PXI-6255 data sheet. To see this PDF, click the link to view the requested file: pci-pxi-pcie-6509-user. The PXI‑6509 can directly drive external digital devices such as solid-state relays (SSRs). Find many great new & used options and get the best deals for 1PC National Instruments NI PXI-6509 PXI Digital I/O Module USED at the best online prices at eBay! Free shipping for many products!Find many great new & used options and get the best deals for National Instruments NI PXI-6509 PXI Digital I/O Module(PXI 6509) at the best online prices at eBay! Free shipping for many products!On the Menu Bar, click Help >> Find Examples. PXIe, 20 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. PXI Platform Services is required to identify NI PXI and PXI Express chassis and modules, as well as to allow for trigger routing. Note For information about using the USB-6509 device, refer to the NI USB-6509 User Guide and Specifications document. 提供pxi-6509说明书文档免费下载,摘要:用户指南和产品规范ni6509注本文档主要介绍nipci-6509、nipxi-6509以及nipcie-6509数据采集设备与ni-daqmx驱动程序软件配合使用的方法。关于使用niusb-6509设备的详细信息,见niusb-6509uSpecification, Revision 2. This category refers to measurements on hard-wired equipment such as equipment in fixed installations, distribution boards, and circuit breakers. Price may vary with addition of accessories and services. Standard Package. 1 and later) Low-cost solution with. Greetings, Yes, pins 50 and 100 are internally connected. DXF. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. 5 V, and. 3 V to 50 V. You can configure each port for input or output, and no external power supply is required for outputs. Navigate to and select the firmware image file saved in step 1, then click the Open button. . com +86 17750010683We're using a PXI-6509 DIO instrument in an application where a number of configured input channels are connected to hardware-under-test that keeps these signals tri-stated most of the time. The failed chips have IO pins shorted. This solution might also apply to other similar products or applications. The maximum bandwidth for PXI chassis is 132MB/s. You can configure each port for input or output, and no external power supply is required for outputs. If a computer or application fault occurs, the PXI‑6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Fast Quotes & Shipping. 37. 96. Feature Usage. Elijah_K. 0 V. Contact us. The PXIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. In contrast, the PCI-6509, PXI-6509, and USB-6509 cannot be configured line-by-line for input or output. Then Select DAQmx. NI 6509 User Guide and Specifications 6 ni. Good luck with your application. DAQmxCreateTask 2. Note For information about using the NI USB-6509 device, refer to the NI USB-6509. NI 6509. Media Storage) Target Data Type Size Battery Backup User Accessible System Accessible This document contains information about using the PCI-6509, PXI-6509, and PCIe-6509 data acquisition devices with the NI-DAQmx driver software. Right-click on your device again and select Reset for the settings to take effect. The PXIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). By clicking the button, you are providing Keysight with your personal data. If you need to read 3. TheNI 6509. Manuals. If the task acquires samples continuously and you set this parameter to -1, this function reads all the samples currently available in the buffer. You can configure each port for input or output, and no external power supply is required for outputs. The National Instruments PXI-6255 is a PXI based M Series card. The counter counts the quantity of rising (or falling) edges in the source signal while the pulse in the Gate. . 5 to 5. 25 of the Users guide, in the dgital I/O specifications, it is stated that the power-on state of the input lines of the NI PXI/PCI 6509 is high Z (default setting) and the inputs can pe pulled up or down (software selectable). For more information about PXI compatibility with PXIe chassis, consult the knowledge base article PXI Card Compatibility With PXIe Chassis . The PXI-6509 (Part Number: 778858-01) Digital I/O Module by National Instruments has 96 digital I/O lines, single-ended signaling, 0 V to 5 V output voltage range, a digital input voltage range of -0. Ting1224. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design. Using programmable power-up states, you can configure the initial output states in. 785024-01 – DAQ Connector Block for use with PXIe-6509 from NI. - 26 May. This document contains information about using the PCI-6509, PXI-6509, and PCIe-6509 data acquisition devices with the NI-DAQmx driver software. You can request repair, RMA, schedule calibration, or get technical support. 8 Weeks. Work with our experts to sustain your critical applications. NI-488. 96-Channel, 5 V, TTL/CMOS, 24 mA, PCI Digital I/O Device. Fran ais Deutsch This document contains information about using the NI PCI-6509, NI PXI-6509, and NI PCIe-6509 data acquisition devices with the NI-DAQmx driver software. Manufacturer Standard Lead Time. Use the optional 12 VDC power supply for additional sourcing current. 3D CAD 모델. TheNI. National Instruments PXI-6255 PXI Multifunction I/O Module. Now, when you go to the Modules tab, you will notice that the incompatible cards are grayed out. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. + 2. . Download. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. The nature of the pull resistors is to ensure that there are no floating lines at any time, and instead always go to either the logical 0 or 1. We've observed that these signals are prone to floating up or down somewhat non-deterministically. • Measurement Category III is for measurements performed in the building installation at the distribution level. Migrating existing applications to the new product may require some. However, if you are outputting signals to a device that. Right-click on your device and select Configure. If you want to read the whole 14 page document,please. . Curtiss-Wright offers a wide selection of analog signal acquisition modules from sensors such as thermocouples, strain gauges, and accelerometers. Fast Quotes & Shipping. Description. Email: info@artisantg. 2770-785024-01. The NI 6509 is a 96-bit, high-drive digital. PCI-6509는 8라인짜리 12개의 양방향 포트를 갖고 있지만, 각 포트는 포트 단위로 입력과. Get shipping and tax estimate by adding the item into your shopping cart. After installation, you will need to install the corresponding software that matches the OS and controller model:This chassis driver provides access to the functionality of the Keysight PXIe Chassis through a . . I have connected the pin 51-53-. Environmental Characteristics The National Instruments PXIe-6509 (Part Number: 787358-01) is a powerful PXI Digital I/O Module that boasts 96 input/output channels. Shipping & Delivery. The NI 6509 is a 96-bit, high-drive digital input/output (DIO) device. PXI-6509. TheNI. Using programmable power-up states. Using the PXIe-6509 programmable power-up states. In contrast, the PCI-6509, PXI-6509, and USB-6509 cannot be configured line-by-line for input or output. PXI-6509. com. 75 baths property. Using the PXIe-6509 programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe. You can configure each port for input or output, and no external power supply is required for outputs. NI PXI-6509, and NI PCIe-6509 data acquisition devices with the NI-DAQmx driver software. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF Product Support Resources. The PCI/PXI system . I bought a new PXI/PXIe real time controller and I would like to start programming it. A valid service agreement may be required. Contact. Default Pin Number.